Sealing element energiser |
 |
Instant fillup & circulation |
 |
Mudloc mudsaver valve prevents spillage |
 |
Single connection to top drive |
 |
The SDT MUD-STINGER (patent pending) incorporates the patented "MUDLOC" mudsaver valve to prevent spillage on and around the rig floor. |
 |
The "MUD-STINGER" permits casing fillup and circulation of the well at any time, helping to avoid stuck pipe problems before they happen. |
 |
The sealing element energiser ensures positive sealing of the circulating annulus. |
MUD-STINGER OPERATION
PRE RIG-UP PROCEDURE
- First, check that the seal cup, (pt.no.: 7) is the correct O.D. to suit the casing weight to be run. (Each cup is labelled).
- Check that all three (3) Allen Screws (pt.no.: 2) are tight.
- After making up to top-drive, kick in circulating pump and check that the mudloc Mud-Saver is working correctly.
- Check that the Seal Cup, (pt.no.: 7) is at least level with the bottom of the elevator, this will ensure that the cup is well inside the casing and below the coupling.
SERVICING PROCEDURE
TO CHANGE-OUT SEAL CUP, BULL-NOSE OR PISTON O' RINGS
- Back-out the three (3) Allen screws, (pt.no.: 2) approx. 1/2"
- Back off the Bull-Nose Sub, (pt.no.: 10) using a chain tong on the retainer sub, (pt. no.: 1) and another on the Bull-Nose. Separate and remove the Seal Cup, (pt.no.: 7) and the Compression Spring, (pt.no.: 8).
- Clean and lubricate the Mandrel, (pt.no.: 6) and replace the Compression Spring and new Seal Cup.
- Check the O' Ring, (pt.no.: 3) and replace if required, remake the the connection using chain tongs, remove one Allen Screw and ensure the Allen Screw groove is in the correct position before re-tightening the three (3) Allen Lock Screws.
- Should the PIston Seals, (pt.no.: 4 & pt.no: 9) - Fail, carry out steps 1 & 2 above and remove Piston, (pt.no.: 5), clean and lubricate the area. Replace O' Rings and re-assemble.
TO SERVICE MUDLOC MUD-SAVER VALVE
(Refer to "Mudloc" Manual)
NOTE:
It is considered extremely unlikely that the Compression Spring will ever require changing during the life of the tool.
|
|